The maintenance of small wind turbines

A small, use and maintenance rules
(1) users and small wind generators use management personnel, we must strive to learn of the small fan expertise, skilled grasp of the construction of small wind turbine principles and proper use and maintenance methods, continue to accumulate experience.
(2) the establishment of day-to-day use and maintenance, the use of regular maintenance system. Daily use and maintenance, is frequently and carefully check the small wind turbine ministries fastening and all major components are functioning normally. Regular use and maintenance, preventive is the regular inspection, periodic lubrication, the main components of the fan to clean the disintegration of the wear and tear of parts to be replaced, the ministries space to re-adjust.
(3) the maintenance of small wind turbines, in particular, regular maintenance, use and management of personnel and related technologies for the field to participate personally get involved, on the one hand can understand the use of master fan, on the other hand, can be found in use The issues, we must uphold the use and maintenance of organic integration.
(4) no ill small wind turbine operation, not overloaded with work, no unauthorized changes to the original design devices.
(5) To establish a technological system files, users and the use of air units, the wind hunger and battery and the use of technology should do well documented. Its contents should include: Fan #; fans bring tools, spare parts and the use of manuals and other technical documentation, commissioning fan, use the work completed in a few hours, technical maintenance and repair records. Fan files technology to improve the use of management level, improve air quality and structural design process has - the significance.
(6) the use of small wind turbines and maintenance in two parts, and - for some fans; storage batteries into the second part. Fans of the battery and energy storage as part of the use and maintenance of two separate elements should be developed separately use and maintenance of order.
Second, the fan part of the maintenance and use of
After the installation of small wind turbines, it has always been in the harsh test of nature, Hanlaishuwang, year after year. Apart from the sun and rain and snow Fengshuang withstand the attack, but also may have been thunder and lightning, hail and wind attacks and the impact of livestock. The working environment is very bad. So for small wind power generators of the proper use and maintenance is particularly important.
(A) the use of content and attention to maintenance issues
1. Fans observe the attention of wind round the normal functioning normally should always observe the functioning of fan wind round, if not a smooth operation, a keen nose jitter or unusual noises, should immediately rule out the check stands. For variable pitch speed of the wind round should always read speed spiral groove back part of the agreement, the survey whether the action flexible.
2. Column Lasso check each fan wire rope cable is firmly reliable post-Lasso small wind generators should always check whether the cable anchored to a solid. Wire Shengsheng folder whether retention. And should always check whether each cable tension wire rope, cable, if necessary, is spiral-deduction, tightening or relaxation.
3. Regular lubrication of small wind turbine rotating major components, such as wind round, generators, installed in the tail, all of the Rotary. Rotary sets of body length of the optical axis and the top post should maintain a good lubrication. To maintain the flexibility to turn tail wind, wind turbine round the wind. Fans generally work six months to one year should be rotating disassemble, clean and scrub (petrol cleansing dip), re-lubricants (Ca-butter). Note that the top of a column optical axis bearing pressure at the same time to clean, good butter and coated with back in situ.
». Regular lubrication generators before and after bearing generators before and after bearing maintenance every six months or a year. Maintenance of generators will be removed, will cover around with Gaizhui gently prised open, attention should not be demolished or Mengli Open rotation, so as not to damage the internal lines or generators rectifier components, remove the cover before and after the use of petrol after the clean , Relubricants (Ca-butter), and cover the requirements of equipment before and after the return to the original.
5. Variable pitch wind round of regular inspections and maintenance of variable pitch due to wind round in the long-term nature of the work, resulting in the wind round lead slot variable pitch slider and spring, and other parts easily Nianman surface dust, the impact of wind round the variable pitch governor Sensitivity and consistency. So, every six months or a year should be a maintenance check. Maintenance, will remove the wind round, removed the blade and used gasoline to clean guide slot, slide and spring, and other parts, after the clean can be loaded back in situ. After cleaning the attention of the general not to increase oil, lubricants because of nude Luzaiwaimian will soon Nianman dust. In addition, the two parts on the leaves after washing the demolition can not be interchangeable, so as not to undermine the balance of wind round.
6. Carbon Brush, slip ring and the seizure of the regular check and maintenance work for small wind turbines, rotating head of the tail will be in effect, as the wind direction changes often wind rotation, resulting in generators due to power lines inside the winding And broken. To address this - the problem, many small wind generator power lines are divided into two sections. On the lead paragraph from the generator to the bottom of the Rotary slip ring, the next paragraph, through carbon brush and slip ring firmly Press. Fan work, because the slip ring constantly rotating and fixed carbon brush through the post-carbon brush on the location and, through spring closely with the slip ring in the Tonghuan Press, often in a rotary friction and nature The invasion of sandstorms. So, every six months or a year should be a maintenance check. Maintenance, will remove carbon brush, wear inspection, if necessary, replaced. With the brush will slip ring inside the dust cleared, and then re-installed in-situ to return.
7. wind Generator power lines into the joint inspection and maintenance has been on generator power lines above are generally divided into two sections, namely the upper and lower. Inserted a paragraph on the joint use of the TV output will be in line with the slip ring Yinchu Xian phase grounding, the following paragraph is inserted with a joint Carbon Brush will lead the next phase grounding of the transmission line (for plugs and sockets are split, the negative electrode positioning plug, General will not be inserted wrong). But power lines are inserted joint Ying Su made the long-term nature of the state of nudity, went into dust or even deformation. So every six months or a year should be a maintenance check. Maintenance, will remove carbon brush, wear inspection, if necessary, replaced. With the brush will slip ring inside the dust cleared, and then re-installed in-situ to return.